Model:UY2500
Price: negotiable
Color: Black/Silver
Dimension:340mm×150mm×90mm
Model selection reference:
UY-2500W-54.6V/40A | 54.6V40A | 13 Series Li-ion/polymer battery |
UY-2500W-58.4V/40A | 58.4V/40A | 16 Series lifepo4 battery |
UY-2500W-72V/23A | 72V/23A | 24 Series Li-ion/polymer battery |
Table 3. Electronic characteristics
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 200 | 220 | 260 | |
02 | Input power | W | – | – | 2519 | |
04 | Constant charge voltage | Vdc | 54.3 | 54.6 | 54.9 | |
05 | Float voltage(for lead acid battery only) | Vdc | – | – | – | |
06 | Constant charge current | A | 37 | 38 | 39 | |
07 | Charge complete current | A | 2.89 | 3.04 | 3.19 | 8%CC |
08 | Ripple voltage | mV | – | – | 500 | |
09 | Efficiency | % | 85 | – | – | Full load |
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. It will restore to normal working condition automatically after troubleshooting.
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. It will restore to normal working condition automatically after troubleshooting.
When the charger has short circuit at output, the charger enters short-circuit protection status. It will restore to normal working condition automatically after troubleshooting.
When the charger output positive negative pole and battery pack are connected in reverse, the internal relay of the charger is not sucked and there is no voltage current at the output terminal of the charger. After the correct connection, the charger can be charged normally.
When charger internal temperature exceed 75℃, it will be Into the over-temperature protection state and the cuts off output .When the temperature returns to 65℃, the charge is restored again.
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 2000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |
With max input and full load, the leakage current < 0.75m A, meet to Class II.
Model:UY1500
Price: negotiable
Color: Black/Silver
Dimension:290mm×150mm×90mm
Model selection reference:
UY-1500W-16.8/60 | 16.8V/60A | 4Sseries Li-ion/polymer battery |
UY-1500W-14.6/60 | 14.6V/60A | 4Sseries LiFePo4 battery |
UY-1500W-14.7/60 | 14.7V/60A | 4Sseries Lead acid battery |
UY-1500W-29.4/45 | 29.4V/45A | 7Sseries Li-ion/polymer battery |
UY-1500W-42/30 | 42V/30A | 10Sseries Li-ion/polymer battery |
UY-1500W-54.6/25 | 54.6V/25A | 13Sseries Li-ion/polymer battery |
UY-1500W-71.4/20 | 71.4V/20A | 17Series Li-ion/polymer battery |
UY-1500W-100.8/13 | 100.8V/13A | 20Series Li-ion/polymer battery |
Table 3. Electronic characteristics
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 90 | 110 | 130 | |
02 | Input power | W | – | – | 1784.2 | |
04 | Constant charge voltage | Vdc | 100.5 | 100.8 | 101.1 | |
05 | Float voltage(for lead acid battery only) | Vdc | \ | \ | \ | |
06 | Constant charge current | A | 13 | 14 | 15 | |
07 | Charge complete current | A | 1 | 1.12 | 1.27 | |
08 | Ripple voltage | mV | – | – | 500 | |
09 | Efficiency | % | 85 | – | – | Full load |
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. It will restore to normal working condition automatically after troubleshooting.
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. It will restore to normal working condition automatically after troubleshooting.
When the charger has short circuit at output, the charger enters short-circuit protection status. It will restore to normal working condition automatically after troubleshooting.
When the charger output positive negative pole and battery pack are connected in reverse, the internal relay of the charger is not sucked and there is no voltage current at the output terminal of the charger. After the correct connection, the charger can be charged normally.
When charger internal temperature exceed 75℃, it will be Into the over-temperature protection state and the cuts off output and the cooling fan is still working. When the temperature returns to 65℃, the charge is restored again.
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 10000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |
UY-1200W-16.8/50 | 16.8V/50A | 4Sseries Li-ion/polymer battery |
UY-1200W-14.6/50 | 14.6V/50A | 4Sseries LiFePo4 battery |
UY-1200W-14.7/50 | 14.7V/50A | 4Sseries Lead acid battery |
UY-1200W-29.4/35 | 29.4V/35A | 8Sseries Li-ion/polymer battery |
UY-1200W-42/25 | 42V/25A | 10Sseries Li-ion/polymer battery |
UY-1200W-54.6/20 | 54.6V/20A | 13Sseries Li-ion/polymer battery |
UY-1200W-71.4/15 | 71.4V/15A | 17Series Li-ion/polymer battery |
UY-1200W-100.8/10 | 100.8V/10 | 20Series Li-ion/polymer battery |
Table 3. Electronic characteristics
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 200 | 220 | 260 | |
02 | Input power | W | – | – | 912 | |
03 | Constant charge voltage | Vdc | 14.3 | 14.6 | 14.9 | |
04 | Float voltage(for lead acid battery only) | Vdc | – | – | – | |
05 | Constant charge current | A | 48 | 50 | 52 | |
06 | Charge complete current | A | 3.85 | 4.0 | 4.15 | |
07 | Ripple voltage | mV | – | – | 500 | |
08 | Efficiency | % | 85 | – | – | Full load |
2. Protect Characteristics.
2.1 Output Over Voltage Protection
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. It will restore to normal working condition automatically after troubleshooting.
2.3 Output Over Current Protection
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. It will restore to normal working condition automatically after troubleshooting.
2.4 Short Circuit Protection
When the charger has short circuit at output, the charger enters short-circuit protection status. It will restore to normal working condition automatically after troubleshooting.
2.5 Reverse Polarity Protection
When the charger output positive negative pole and battery pack are connected in reverse, the internal relay of the charger is not sucked and there is no voltage current at the output terminal of the charger. After the correct connection, the charger can be charged normally.
2.6 Over-Temperature protection
When charger internal temperature exceed 75℃, it will be Into the over-temperature protection state and the cuts off output .When the temperature returns to 65℃, the charge is restored again.
3. Environmental
3.1 Working Conditions
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 2000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
5. Safety.
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |
With max input and full load, the leakage current < 0.75m A, meet to Class II.
UY-2000A-73/20RO | 73V/20A | 20series LiFePo4 battery |
UY-2000A-87.6/20RO | 87.6V/20A | 24series LiFePo4 battery |
UY-2000A-58.8/30R0 | 58.8V/15A | 14S Li-ion/polymer battery |
UY-2000A-58.4/30RO | 58.4V/15A | 16Sseries LiFePo4 battery |
UY-2000A-43.8V/40R0 | 43.8V40A | 12series LiFePo4 battery |
UY-2000A-42V/40R0 | 42V40A | 10 series Li-ion/polymer battery |
Table 3. Electronic characteristics
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 200 | 220 | 264 | |
02 | Input power | W | – | – | 2061 | |
03 | Constant charge voltage | Vdc | 87.3 | 87.6 | 87.9- | |
04 | Float voltage(for lead acid battery only) | Vdc | – | – | – | |
05 | Constant charge current | A | 19 | 20 | 21 | |
06 | Charge complete current | mA | 900 | 1000 | 1100 | |
07 | Ripple voltage | mV | – | – | 500 | |
08 | Efficiency | % | 85 | – | – | Full load |
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. Troubleshooting can be automatically restored to normal working condition.
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. Troubleshooting automatically restored to normal working condition.
When the charger has short circuit at output, the charger enters short-circuit protection status. Troubleshooting automatically return to normal working condition.
If charger DC output terminal connect to battery reverse, fuse on the output side would be fuse, output circuit would be cut off. Replace the fuse, and then connect to battery correctly, charger would resume working.
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 10000 meter;
Cooling: BAL series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
4. Reliability
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |
With max input and full load, the leakage current < 0.75m A, meet to Class II.
EN 55022:2006+A1:2007
EN 61000-3-2:2006+A1:2009+A2::2009
EN 61000-3-3:2008
EN 55024:1998+A1:2001+A2:2003
Conducted interference: EN55011.13.14-1.15.22.FCC part 15&18.VCCI;
Radiated interference: EN55011.13.22.FCCpart 15&18.VCCI/EN55013.EN55014-1.
Anti-static: IEC/EN61000-4-2 8KV;
Pulse group: IEC/EN61000-4-4 2KV;
Lightning surge: IEC/EN61000-4-5 1.5KV;
Harmonic: IEC/EN61000-3-2 <25%.
Model:UY900
Price: negotiable
Color: Black/Silver
Dimension:305mm×150mm×90mm
Model selection reference:
UY-900A-29.4/30 | 29.4V/30A | 7series Li-ion/polymer battery |
UY-900A-69.35/10 | 69.35V/10A | 19series LiFePo4 battery |
UY-900A-73/10 | 73V/10A | 20series LiFePo4 battery |
UY-900A-74/10 | 74V/10A | 18series Li-ion/polymer battery |
UY-900A-87.6/10 | 87.6V/10A | 24series LiFePo4 battery |
UY-900A-102.2/08 | 102.2V/8A | 28series LiFePo4 battery |
UY-900A-109.5/08 | 109.5V/8A | 28series LiFePo4 battery |
UY-900A-58.8/15 | 58.8V/15A | 14S Li-ion/polymer battery |
UY-900A-58.4/15 | 58.4V/15A | 16Sseries LiFePo4 battery |
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 200 | 220 | 264 | |
02 | Input power | W | – | – | 1041 | |
03 | Constant charge voltage | Vdc | 82.7 | 84.0 | 84.3- | |
04 | Float voltage(for lead acid battery only) | Vdc | – | – | – | |
05 | Constant charge current | A | 9.5 | 10 | 10.5 | |
06 | Charge complete current | mA | 400 | 500 | 600 | |
07 | Ripple voltage | mV | – | – | 250 | |
08 | Efficiency | % | 85 | – | – | Full load |
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. Troubleshooting can be automatically restored to normal working condition.
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. Troubleshooting automatically restored to normal working condition.
When the charger has short circuit at output, the charger enters short-circuit protection status. Troubleshooting automatically return to normal working condition.
If charger DC output terminal connect to battery reverse, fuse on the output side would be fuse, output circuit would be cut off. Replace the fuse, and then connect to battery correctly, charger would resume working.
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 10000 meter;
Cooling: BAL series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |
With max input and full load, the leakage current < 0.75m A, meet to Class II.
EN 55022:2006+A1:2007
EN 61000-3-2:2006+A1:2009+A2::2009
EN 61000-3-3:2008
EN 55024:1998+A1:2001+A2:2003
Conducted interference: EN55011.13.14-1.15.22.FCC part 15&18.VCCI;
Radiated interference: EN55011.13.22.FCCpart 15&18.VCCI/EN55013.EN55014-1.
Anti-static: IEC/EN61000-4-2 8KV;
Pulse group: IEC/EN61000-4-4 2KV;
Lightning surge: IEC/EN61000-4-5 1.5KV;
Harmonic: IEC/EN61000-3-2 <25%.
1.Summary:
DLS16B14B-01T40AThis specification applies to the 14Series lithium battery Protection Circuit Module Products are RoHS compliant.
With over charge function, over discharge function, over current protection, short circuit protection, temperature function, charging balance management function and so on.
Apply seiko solution which is IC A grade protection
With strong loaded, constant discharging current is 40A, MOSFET with high stand voltage and low conduction internal independence. Cooling fin effect is good。
IC have power balancing function, current could be adjusted by improve the MOSFET。
Over charge protection, over discharge protection, typical voltage detection method.Over current, short circuit protection, short circuit protection performance is stable and reliable, long time load short circuit will not affect the protection board and electric core
Temperature protection during charge and discharge。
Temperature drift is tiny, the accuracy is 1% high power package detection resistance。
Extremely low power consumption, the whole machine consumes less than 50uA。
PCBA surface with high corrosion resistance, high permeability, high impedance coating ESD paint three.
The direct series combination of 14 supported multi compound lithium power battery。
3.Picture:
PCBA Drawing
4.Characteristic:(li-ion battery)
Detailed contents
Specification
Detailed contents | Specification | Unit | Remark | |
Discharge | Constant discharge current | 40 | A | |
instant discharge current | 100 | A | ||
Charge | charge voltage | 58.8 | V | |
charge current | 40(MAX) | A | ||
Over charge protection | over charge voltage | 4.3±0.025 | V | |
over charge protect delay | 0.5 | S | ||
Over charge release voltage | 4.1±0.05 | V | ||
Power balance
|
Power balance detect voltage | 4.18 | V | |
Power balance release voltage | 4.18 | V | ||
Power balance current | 35±5 | mA | ||
Over discharge protection | Over discharge detect voltage | 2.5±0.05 | V | |
Over discharge detect delay | 0.5 | S | ||
Over discharge release voltage | 2.9±0.1 | V | ||
Over current protect | Over current detect voltage | 100 | mV | |
Over current detect delay | 9 | MS | ||
Over current protect current | 100±5 | A | Customized | |
Over current protect release condition | Off-load | |||
Short circuit protect | Short circuit protect condition | outside load short circuit | ||
Short circuit detect delay | 250 | uS | ||
Short circuit protect release condition | Off-load | |||
Temperature protect | Temperature protection | ℃ | Customized | |
Internal insistance | The main circuit conduction resistance | ≤10 | mΩ | |
Consumable | Working current | ≤50 | uA | |
Sleep current(battery over discharge) | ≤12 | uA | ||
Working temperature | Temperature range | -30/+80 | ℃ |
5.Interface definition
B- is connected to the negative terminal of the battery pack
P-is connected to negative terminal of load
CN1:cell voltage detect terminal。
1.Summary:
DLS14A11B-01T16AThis specification applies to the 11Series lithium battery Protection Circuit Module . Products are RoHS compliant.
With over charge function, over discharge function, over current protection, short circuit protection, temperature function, charging balance management function and so on.
Apply seiko solution which is IC A grade protection
With strong loaded, constant discharging current is 16A, MOSFET with high stand voltage and low conduction internal independence. Cooling fin effect is good。
IC have power balancing function, current could be adjusted by improve the MOSFET。
Over charge protection, over discharge protection, typical voltage detection method.Over current, short circuit protection, short circuit protection performance is stable and reliable, long time load short circuit will not affect the protection board and electric core
Temperature protection during charge and discharge。
Temperature drift is tiny, the accuracy is 1% high power package detection resistance。
Extremely low power consumption, the whole machine consumes less than 50uA。
PCBA surface with high corrosion resistance, high permeability, high impedance coating ESD paint three.
The direct series combination of 13 supported multi compound lithium power battery。
3.Picture:
4.Characteristic:(li-ion battery)
Detailed contents | Specification | Unit | Remark | |
Discharge | Constant discharge current | 16 | A | |
instant discharge current | 45 | A | ||
Charge | charge voltage | 46.2 | V | |
charge current | 16(MAX) | A | ||
Over charge protection | over charge voltage | 4.3±0.05 | V | |
over charge protect delay | 0.5 | S | ||
Over charge release voltage | 4.1±0.05 | V | ||
Power balance
|
Power balance detect voltage | 4.18 | V | |
Power balance release voltage | 4.18 | V | ||
Power balance current | 35±5 | mA | ||
Over discharge protection | Over discharge detect voltage | 2.5±0.1 | V | |
Over discharge detect delay | 0.5 | S | ||
Over discharge release voltage | 2.9±0.1 | V | ||
Over current protect | Over current detect voltage | 150 | mV | |
Over current detect delay | 9 | MS | ||
Over current protect current | 55±10 | A | ||
Over current protect release condition | Off-load | |||
Short circuit protect | Short circuit protect condition | outside load short circuit | ||
Short circuit detect delay | 250 | uS | ||
Short circuit protect release condition | Off-load | |||
Temperature protect | Temperature protection | — | ℃ | |
Internal insistance | The main circuit conduction resistance | ≤10 | mΩ | |
Consumable | Working current | ≤50 | uA | |
Sleep current(battery over discharge) | ≤12 | uA | ||
Working temperature | Temperature rang | -30/+80 | ℃ |
5.Interface definition
B- is connected to the negative terminal of the battery pack
P-is connected to negative terminal of load
CN1:cell voltage detect terminal。
6 Operation:
6.1:The connecting sequence of the electrical core is: first, then B-, and then connected with the cell voltage detection terminal, and the reverse sequence is removed.。
6.2:Cell voltage detection terminal use spacing of 2.0 cable connection, the cN1 1 foot for B-, the second foot B1, the tripod for B2, followed by analogy, 12 feet to B +
6.3:Battery voltage detection lines using a standard cable, B -, P – and need to according to the continuous discharge current and the charging current to the size of the selection of suitable wire diameter of wire.
6.4:After the battery and protective board is connected, the voltage between P- and B+ is measured, if measured the voltage is equal to the total voltage of the battery pack, indicating that the protection board has been working properly.
Note: the BMS is connected to the cell, or from the battery pack, must follow the above order, such as not in accordance with the requirements of the order of operations, will damage the components of the protection board, causing serious consequences.
7:Dimension:65*33*10mm
DLS10A10B-01This specification applies to the 10Series lithium battery Protection Circuit Module . Products are RoHS compliant.
With over charge function, over discharge function, over current protection, short circuit protection, temperature function, charging balance management function and so on.
Apply seiko solution which is IC A grade protection
With strong loaded, constant discharging current is 16A, MOSFET with high stand voltage and low conduction internal independence. Cooling fin effect is good。
IC have power balancing function, current could be adjusted by improve the MOSFET。
Over charge protection, over discharge protection, typical voltage detection method.Over current, short circuit protection, short circuit protection performance is stable and reliable, long time load short circuit will not affect the protection board and electric core
Temperature protection during charge and discharge。
Temperature drift is tiny, the accuracy is 1% high power package detection resistance。
Extremely low power consumption, the whole machine consumes less than 50uA。
PCBA surface with high corrosion resistance, high permeability, high impedance coating ESD paint three.
The direct series combination of 7-10 supported multi compound lithium power battery。
3.Picture:
Before adding cooling fin
After adding cooling fin
4.Characteristic:(li-ion battery)
Detailed contents | Specification | Unit | Remark | |
Discharge | Constant discharge current | 16 | A | |
instant discharge current | 35A | A | ||
Charge | charge voltage | 42 | V | |
charge current | 8 MAX | A | ||
Over charge protection | over charge voltage | 4.25±0.025 | V | |
over charge protect delay | 0.5 | S | ||
Over charge release voltage | 4.1±0.05 | V | ||
Power balance
|
Power balance detect voltage | 4.175±0.025 | V | |
Power balance release voltage | 4.175 | V | ||
Power balance current | 35±5 | mA | ||
Over discharge protection | Over discharge detect voltage | 2.8±0.05 | V | |
Over discharge detect delay | 0.5 | S | ||
Over discharge release voltage | 2.9±0.1 | V | ||
Over current protect | Over current detect voltage | 100±15 | mV | |
Over current detect delay | 9 | MS | ||
Over current protect current | 35±5 | A | ||
Over current protect release condition | Off-load | |||
Short circuit protect | Short circuit protect condition | outside load shor circuit | ||
Short circuit detect delay | 250 | uS | ||
Short circuit protect release condition | Off-load | |||
Temperature protect | Temperature protection | 60 | ℃ | |
Internal insistance | The main circuit conduction resistance | ≤10 | mΩ | |
Consumable | Working current | ≤50 | uA | |
Sleep current(battery over discharge) | ≤10 | uA | ||
Working temperature | Temperature rang | -30/+80 | ℃ |
5.Interface definition
B- is connected to the negative terminal of the battery pack
C-:is connected to the charger negative .
P-is connected to negative terminal of load
CN1:cell voltage detect terminal。
B-270MM long,AWG16 silicone line,200℃,600V black
P-110MM long,AWG16 silicone line,200℃,600V blue
C-110MM long,AWG18 silicone line,200℃,600V yellow
Sampling line 450MM,AWG24
Summary:
DLS07A07B-01F20A This specification applies to the 7Series lithium battery Protection Circuit Module. Products are RoHS compliant.
With over charge function, over discharge function, over current protection, short circuit protection, temperature function, charging balance management function and so on.
Apply seiko solution which is IC A grade protection
With strong loaded, constant discharging current is 20A, MOSFET with high stand voltage and low conduction internal independence. Cooling fin effect is good。
IC have power balancing function, current could be adjusted by improve the MOSFET。
Over charge protection, over discharge protection, typical voltage detection method.Over current, short circuit protection, short circuit protection performance is stable and reliable, long time load short circuit will not affect the protection board and electric core
Temperature protection during charge and discharge。
Temperature drift is tiny, the accuracy is 1% high power package detection resistance。
Extremely low power consumption, the whole machine consumes less than 50uA。
PCBA surface with high corrosion resistance, high permeability, high impedance coating ESD paint three.
The direct series combination of 7 supported multi compound lithium power battery。
3.Picture:
4.Characteristic:(li-ion battery)
Detailed contents | Specification | Unit | Remark | |
Discharge | Constant discharge current | 20 | A | |
instant discharge current | 45 | A | ||
Charge | charge voltage | 29.4 | V | |
charge current | 10 MAX | A | ||
Over charge protection | over charge voltage | 4.3±0.5 | V | |
over charge protect delay | 0.5 | S | ||
Over charge release voltage | 4.1±0.05 | V | ||
Power balance
|
Power balance detect voltage | 4.18 | V | |
Power balance release voltage | 4.18 | V | ||
Power balance current | 35 | mA | ||
Over discharge protection | Over discharge detect voltage | 2.5±0.1 | V | |
Over discharge detect delay | 0.5 | S | ||
Over discharge release voltage | 2.9±0.1 | V | ||
Over current protect | Over current detect voltage | 150±15 | mV | |
Over current detect delay | 9 | MS | ||
Over current protect current | 45±5 | A | ||
Over current protect release condition | Off-load | |||
Short circuit protect | Short circuit protect condition | outside load shor circuit | ||
Short circuit detect delay | 250 | uS | ||
Short circuit protect release condition | Off-load | |||
Temperature protect | Temperature protection | 60 | ℃ | |
Internal insistance | The main circuit conduction resistance | ≤10 | mΩ | |
Consumable | Working current | ≤50 | uA | |
Sleep current(battery over discharge) | ≤10 | uA | ||
Working temperature | Temperature rang | -30/+80 | ℃ |
5.Interface definition
B- is connected to the negative terminal of the battery pack
C-:is connected to the charger negative .
P-is connected to negative terminal of load
CN1:cell voltage detect terminal。
Sampling line 450MM,AWG24
6 Operation:
6.1:The connecting sequence of the electrical core is: first, then B-, and then connected with the cell voltage detection terminal, and the reverse sequence is removed.。
6.2:Cell voltage detection terminal use spacing of 2.0 cable connection, the cN1 1 foot for B-, the second foot B1, the tripod for B2, followed by analogy, 8 feet to B +
6.3:Battery voltage detection lines using a standard cable, B-, P-, C- need according to the continuous discharge and the charging current to the size of the selection of suitable diameter of wire
6.4:After the battery and protective board is connected, the voltage between C- and B+ is measured, if measured
The voltage is equal to the total voltage of the battery pack, indicating that the protection board has been working properly.
Note: BMS is connected to the cell, or from the battery pack, must follow the above order, such as not in accordance with the requirements of the order of operations, will damage the components of the protection board, causing serious consequences.
7.Dimension:63*32*10mm(including cooling fin )
Table 3. Electronic characteristics
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 100 | 110/220 | 263 | |
02 | Input power | W | – | – | 77 | |
03 | Constant charge voltage | Vdc | 14.4 | 14.6 | 14.8 | |
04 | Float voltage(for lead acid battery only) | Vdc | ||||
05 | Constant charge current | A | 3.7 | 4 | 4.3 | |
06 | Charge complete current | mA | 300 | 400 | 500 | |
07 | Ripple voltage | mV | – | – | 250 | |
08 | Efficiency | % | 83 | – | – | Full load |
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. Troubleshooting can be automatically restored to normal working condition.
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. Troubleshooting automatically restored to normal working condition.
When the charger has short circuit at output, the charger enters short-circuit protection status. Troubleshooting automatically return to normal working condition.
If charger DC output terminal connect to battery reverse, fuse on the output side would be fuse, output circuit would be cut off. Replace the fuse, and then connect to battery correctly, charger would resume working.
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 10000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |
With max input and full load, the leakage current < 0.75m A, meet to Class II.
EN 55022:2006+A1:2007
EN 61000-3-2:2006+A1:2009+A2::2009
EN 61000-3-3:2008
EN 55024:1998+A1:2001+A2:2003
Conducted interference: EN55011.13.14-1.15.22.FCC part 15&18.VCCI;
Radiated interference: EN55011.13.22.FCCpart 15&18.VCCI/EN55013.EN55014-1.
Anti-static: IEC/EN61000-4-2 8KV;
Pulse group: IEC/EN61000-4-4 2KV;
Lightning surge: IEC/EN61000-4-5 1.5KV;
Harmonic: IEC/EN61000-3-2 <25%.