UY1500-LM8414-1

Model:UY1500

Price: negotiable

Color: Black/Silver

Dimension:290mm×150mm×90mm

Model selection reference:

UY-1500W-16.8/60 16.8V/60A 4Sseries Li-ion/polymer battery
UY-1500W-14.6/60 14.6V/60A 4Sseries LiFePo4 battery
UY-1500W-14.7/60 14.7V/60A 4Sseries Lead acid battery
UY-1500W-29.4/45 29.4V/45A 7Sseries Li-ion/polymer battery
UY-1500W-42/30 42V/30A 10Sseries Li-ion/polymer battery
UY-1500W-54.6/25 54.6V/25A 13Sseries Li-ion/polymer battery
UY-1500W-71.4/20 71.4V/20A 17Series Li-ion/polymer battery
UY-1500W-100.8/13 100.8V/13A 20Series Li-ion/polymer battery

1.    Electronic Characteristics

Table 3. Electronic characteristics

No. Item Unit Min. Typ. Max. Remark
01 Input voltage Vac 90 110 130
02 Input power W 1784.2
04 Constant charge voltage Vdc 100.5 100.8 101.1
05 Float voltage(for lead acid battery only) Vdc \ \ \
06 Constant charge current A 13 14 15
07 Charge complete current A 1 1.12 1.27
08 Ripple voltage mV 500
09 Efficiency % 85 Full load

2.  Protect Characteristics

2.1    Output Over Voltage Protection

When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. It will restore to normal working condition automatically after troubleshooting.

2.2    Output Over Current Protection

When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. It will restore to normal working condition automatically after troubleshooting.

2.3    Short Circuit Protection

When the charger has short circuit at output, the charger enters short-circuit protection status. It will restore to normal working condition automatically after troubleshooting.

2.4    Reverse Polarity Protection

When the charger output positive negative pole and battery pack are connected in reverse, the internal relay of the charger is not sucked and there is no voltage current at the output terminal of the charger. After the correct connection, the charger can be charged normally.

2.5    Over-Temperature protection

When charger internal temperature exceed 75℃, it will be Into the over-temperature protection state and the cuts off output and the cooling fan is still working. When the temperature returns to 65℃, the charge is restored again.

3.    Environmental

3.1    Working Conditions

Ambient temperature: -5℃ ~ +40℃;

RH: 5% ~ 95%;

Max. altitude: 10000  meter;

Cooling: UY series chargers use of forced air cooling system. Under dustless and        ventilated conditions, the full load temperature rise not exceeding 40℃.

3.2    Storage Conditions

Ambient temperature: -40℃ ~ +70℃;

RH: 0% ~ 95%;

Max. altitude: 20000 meter.

4.    Reliability

Table 4. Reliability

No. Item Description Remark
01 MTBF average operating life ≥ 30000h 25℃
02 Anti-vibration 5mm/50Hz/600s vibration test PASS

5. Safety

5.1 Insulation Characteristics

Table 5. Insulation characteristics

Insulation resistant Input to output DC500V 50MΩmin (25℃, Humidity≤70%)
Input to case DC500V 50MΩmin (25℃, Humidity≤70%)
Output to case DC500V 50MΩmin (25℃, Humidity≤70%)
Hi-Pot Input to output 1500Vac 50Hz 1minute ≤10mA
Input to case 1500Vac 50Hz 1minute ≤10mA
Output to case 500Vac 50Hz 1minute ≤10mA