Model:UY1500
Price: negotiable
Color: Black/Silver
Dimension:290mm×150mm×90mm
Model selection reference:
UY-1500W-16.8/60 | 16.8V/60A | 4Sseries Li-ion/polymer battery |
UY-1500W-14.6/60 | 14.6V/60A | 4Sseries LiFePo4 battery |
UY-1500W-14.7/60 | 14.7V/60A | 4Sseries Lead acid battery |
UY-1500W-29.4/45 | 29.4V/45A | 7Sseries Li-ion/polymer battery |
UY-1500W-42/30 | 42V/30A | 10Sseries Li-ion/polymer battery |
UY-1500W-54.6/25 | 54.6V/25A | 13Sseries Li-ion/polymer battery |
UY-1500W-71.4/20 | 71.4V/20A | 17Series Li-ion/polymer battery |
UY-1500W-100.8/13 | 100.8V/13A | 20Series Li-ion/polymer battery |
Table 3. Electronic characteristics
No. | Item | Unit | Min. | Typ. | Max. | Remark |
01 | Input voltage | Vac | 90 | 110 | 130 | |
02 | Input power | W | – | – | 1784.2 | |
04 | Constant charge voltage | Vdc | 100.5 | 100.8 | 101.1 | |
05 | Float voltage(for lead acid battery only) | Vdc | \ | \ | \ | |
06 | Constant charge current | A | 13 | 14 | 15 | |
07 | Charge complete current | A | 1 | 1.12 | 1.27 | |
08 | Ripple voltage | mV | – | – | 500 | |
09 | Efficiency | % | 85 | – | – | Full load |
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. It will restore to normal working condition automatically after troubleshooting.
When the charger output current exceeds the maximum charging current, the charger enters the over current protection status. It will restore to normal working condition automatically after troubleshooting.
When the charger has short circuit at output, the charger enters short-circuit protection status. It will restore to normal working condition automatically after troubleshooting.
When the charger output positive negative pole and battery pack are connected in reverse, the internal relay of the charger is not sucked and there is no voltage current at the output terminal of the charger. After the correct connection, the charger can be charged normally.
When charger internal temperature exceed 75℃, it will be Into the over-temperature protection state and the cuts off output and the cooling fan is still working. When the temperature returns to 65℃, the charge is restored again.
Ambient temperature: -5℃ ~ +40℃;
RH: 5% ~ 95%;
Max. altitude: 10000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated conditions, the full load temperature rise not exceeding 40℃.
Ambient temperature: -40℃ ~ +70℃;
RH: 0% ~ 95%;
Max. altitude: 20000 meter.
Table 4. Reliability
No. | Item | Description | Remark |
01 | MTBF | average operating life ≥ 30000h | 25℃ |
02 | Anti-vibration | 5mm/50Hz/600s vibration test | PASS |
Table 5. Insulation characteristics
Insulation resistant | Input to output | DC500V 50MΩmin (25℃, Humidity≤70%) |
Input to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Output to case | DC500V 50MΩmin (25℃, Humidity≤70%) | |
Hi-Pot | Input to output | 1500Vac 50Hz 1minute ≤10mA |
Input to case | 1500Vac 50Hz 1minute ≤10mA | |
Output to case | 500Vac 50Hz 1minute ≤10mA |